Performance Table
FAN | SPEED | POWER | CURRENT | SOUND dB | AIR | AIR VOLUMES UNDER STATIC PRESSURE | |||||
1-Ph. | 3-Ph. | 0.1″ | 0.2″ | 0.3″ | 0.4″ | 0.5″ | |||||
230V. | 400V. | C.F.M. | C.F.M. | C.F.M. | C.F.M. | C.F.M. | C.F.M. | ||||
m3/h. | m3/h. | m3/h. | m3/h. | m3/h. | m3/h. | ||||||
190mm (7½ “) | 1370 | 35 | 0.16 | – | 45 | 270 | – | – | – | – | – |
230mm (9″) | 1370 | 40 | 0.18 | – | 49 | 440 | 270 | – | – | – | – |
300mm (12″) | 920 | 45 | 0.2 | – | 46 | 750 | – | – | – | – | – |
| 1420 | 82 | 0.38 | 0.20 | 55-60 | 1120 | 900 | 700 | 500 | – | – |
380mm (15″) | 920 | 78 | 0.35 | 0.20 | 50-55 | 1450 | 1090 | 700 | – | – | – |
| 1420* | 150 | 0.70 | 0.40 | 60-65 | 2350 | 1980 | 1780 | 1500 | 1300 | 1020 |
450mm (18″) | 920 | 132 | 0.60 | 0.35 | 55-60 | 2550 | 2030 | 1600 | 1100 | – | – |
| 1420* | 370 | 1.65 | 0.70 | 65 | 4000 | 3500 | 3280 | 3000 | 2800 | 2500 |
600mm (24″) | 720 | 240 | 1.10 | 0.50 | 55-60 | 4650 | 3800 | 3100 | 2300 | – | – |
| 920* | 500 | 2.40 | 0.90 | 60-65 | 6150 | 5300 | 4900 | 4400 | 3800 | 3200 |
900mm (36″) | 570* | 740 | – | 1.50 | 60-65 | 13000 | 10800 | 9800 | 8500 | 7000 | 5000 |
720* | 1200 | – | 2.80 | 65 | 16500 | 14000 | 13100 | 12200 | 11100 | 10000 |
* Not recommended to be used with louvre shutters
50-55 dB: Quiet
55-60 dB: Fairly Quiet
60-65 dB: Normal Industrial Noise
Above 65 dB: Fairly Noise